New enhanced version - features the ability to monitor the voltage of the Starter Battery The BM-1 is designed to monitor performance of 12 volt lead acid battery systems with capacities of up to 650 Amp hours. It is supplied complete with a precision 100 Amp shunt and a prefabricated cable assembly to enable simple DIY installation.
The unit continuously monitors coltage, current (charge of discharge), number of Amp/hours (charge or discharge), the battery's state of charge and the time of charge or discharge. This information leads to more efficient use of the battery, which can ebhance battey life and reduce the risk of failure.
Specifications:
Supply voltage 8-16 Volts DC
Supply current 3 milliAmps
Battery capacities 5-650 Amp hour
Load current 100 Amps maximum
Charge current 100 Amps maximum
Shunt Standard 50 millivolt @ 100 Amp
Cables supplied:
100 Amp shunt link to M8 ring terminal
5 Metre from display unit to battery - fused and fitted with ring terminals for shunt, fuse holder and M8 ring terminal to battery.
Display unit
Standard 100mm square Clipper case. High contrast LCD, backlit for night viewing. Minimum voltage visual alarm. Simple operation - 4 keys to select backlight, Volt/Amp/State of charge screen, Amp hours of Time to run.